KnowledgeBoat Logo
|
OPEN IN APP

Chapter 8

Torque on a Current-Loop : Moving-Coil Galvanometer — Questions

Class 12 - Nootan Physics



Objective Type Questions

Question 1

In a radial magnetic field:

  1. the plane of the coil remains parallel to the lines of forces in every position
  2. it remains perpendicular to the lines of forces
  3. torque experienced by the coil is zero in every position
  4. none of the above

Answer

the plane of the coil remains parallel to the lines of forces in every position

Reason — In a radial magnetic field the lines of force are directed along the radii of the cylindrical soft-iron core. Hence, in every position of the coil its plane remains parallel to the lines of force, so that θ = 90° and the deflecting torque always has its maximum value NIAB.

Question 2

Sensitivity of a moving coil galvanometer can be increased by:

  1. increasing number of turns
  2. increasing magnetic field intensity B
  3. increasing area of the coil
  4. all of the above

Answer

all of the above

Reason — The current sensitivity of a moving coil galvanometer is

ϕI=NABc\dfrac{\phi}{\text I} = \dfrac{\text{NAB}}{\text c}

Hence, the sensitivity increases on increasing the number of turns N, the magnetic field intensity B and the area A of the coil.

Question 3

Phosphor-bronze strip in a suspended coil galvanometer is used as a suspension fibre:

  1. as it is good conductor of electricity
  2. as it does not oxidise at working temperature and its torsion couple per unit twist is least
  3. as it has very less elastic after effect
  4. all of the above

Answer

all of the above

Reason — Phosphor-bronze is a good conductor of electricity, does not oxidise (is rust proof), has a small torsional constant (torsion couple per unit twist) and has very less elastic after effect. All these properties make it suitable for the suspension strip.

Question 4

In an ammeter, 5% of the main current is passing through the galvanometer. If the resistance of the galvanometer is G, then the resistance of the shunt will be:

  1. 19 G
  2. 20 G
  3. G20\dfrac{\text G}{20}
  4. G19\dfrac{\text G}{19}

Answer

G19\dfrac{\text G}{19}

Reason — The current through the galvanometer is Ig = 5% of I = I20\dfrac{\text I}{20}, so the shunt carries the rest, 19I20\dfrac{19\text I}{20}. As G and S are in parallel,

Ig×G=(I−Ig)×SI20×G=19I20×SS=G19\text I_\text g \times \text G = (\text I - \text I_\text g) \times \text S \\[1em] \dfrac{\text I}{20} \times \text G = \dfrac{19\text I}{20} \times \text S \\[1em] \text S = \dfrac{\text G}{19}

Question 5

The resistance of an ammeter formed by converting a galvanometer will be:

  1. equal to galvanometer
  2. less than galvanometer
  3. greater than galvanometer
  4. none of the above

Answer

less than galvanometer

Reason — An ammeter is formed by connecting a small resistance S (shunt) in parallel with the galvanometer coil G. The resistance of the ammeter, RA=GSG+S\text R_\text A = \dfrac{\text{GS}}{\text G + \text S}, is less than even the shunt S, and hence much less than G.

Question 6

A moving coil galvanometer can be converted into a voltmeter by connecting:

  1. a low resistance in series with its coil
  2. low resistance in parallel with its coil
  3. a high resistance in parallel with its coil
  4. a high resistance in series with its coil

Answer

a high resistance in series with its coil

Reason — To convert a galvanometer into a voltmeter its resistance must be increased. So a high resistance R=VIg−G\text R = \dfrac{\text V}{\text I_\text g} - \text G is connected in series with its coil.

Question 7

A circular loop of area A, carrying current I, is placed in a magnetic field B perpendicular to the plane of the loop. The torque on the loop due to magnetic field is:

  1. BIA
  2. 2 BIA
  3. 12\dfrac{1}{2} BIA
  4. zero

Answer

zero

Reason — When B is perpendicular to the plane of the loop, the normal to the loop is along B, i.e., θ = 0°. Hence, τ=BIAsin⁡0∘=0\tau = \text{BIA}\sin 0^\circ = 0.

Question 8

A circular loop of area 1.0 cm2 has a current of 10.0 A flowing through it. A magnetic field of 0.1 tesla is applied parallel to the plane of the loop. Due to the magnetic field the torque acting on the loop will be:

  1. zero
  2. 10-4 N-m
  3. 10-2 N-m
  4. 1.0 N-m

Answer

10-4 N-m

Reason — The field is parallel to the plane of the loop, so the normal to the loop makes θ = 90° with the field and the torque is maximum.

τ=IABsin⁡90∘=10.0×(1.0×10−4)×0.1×1τ=10−4 N m\tau = \text{IAB}\sin 90^\circ \\[1em] = 10.0 \times (1.0 \times 10^{-4}) \times 0.1 \times 1 \\[1em] \tau = 10^{-4}\ \text{N m}

Question 9

A current carrying circular loop of radius R is placed in the x-y plane with centre at the origin. Half of the loop with x > 0 is now bent so that it now lies in the y-z plane.

  1. The magnitude of magnetic moment now diminishes
  2. The magnetic moment does not change
  3. The magnitude of B at (0, 0, z), z >> R increases
  4. The magnitude of B at (0, 0, z), z >> R is unchanged

Answer

The magnitude of magnetic moment now diminishes

Reason — Initially the magnetic moment is m = IπR2, along the z-axis. After bending, each half is a semicircle of area πR22\dfrac{\pi\text R^2}{2}. The half in the x-y plane has a moment m2\dfrac{\text m}{2} along the z-axis and the half in the y-z plane has a moment m2\dfrac{\text m}{2} along the x-axis. The resultant moment is

m′=(m2)2+(m2)2m′=m2\text m' = \sqrt{\left(\dfrac{\text m}{2}\right)^2 + \left(\dfrac{\text m}{2}\right)^2} \\[1em] \text m' = \dfrac{\text m}{\sqrt{2}}

which is less than m. Hence, the magnitude of the magnetic moment diminishes.

Question 10

A circular current loop of magnetic moment M is in an arbitrary orientation in an external magnetic field B⃗\vec{\text B}. The work done to rotate the loop by 30° about an axis perpendicular to its plane, is:

  1. MB
  2. 3MB2\sqrt{3}\dfrac{\text {MB}}{2}
  3. MB2\dfrac{\text {MB}}{2}
  4. zero

Answer

zero

Reason — The magnetic moment M is along the axis of the loop, i.e., perpendicular to its plane. Rotating the loop about this axis does not change the direction of M, so the angle θ between M and B remains the same. The work done, W=MB(cos⁡θ1−cos⁡θ2)\text W = \text{MB}(\cos\theta_1 - \cos\theta_2), is therefore zero.

Question 11

A voltmeter has a resistance of G ohm and a range of V volt. To increase the range up to nV volt, the value of the series resistance used with it, is:

  1. G(n−1)\text G(\text n - 1)
  2. Gn\dfrac{\text G}{\text n}
  3. Gn
  4. Gn−1\dfrac{\text G}{\text n - 1}

Answer

G(n−1)\text G(\text n - 1)

Reason — The current for full-scale deflection is Ig=VG\text I_\text g = \dfrac{\text V}{\text G}. For the range nV with a series resistance R,

Ig=nVG+RVG=nVG+RG+R=nGR=G(n−1)\text I_\text g = \dfrac{\text{nV}}{\text G + \text R} \\[1em] \dfrac{\text V}{\text G} = \dfrac{\text{nV}}{\text G + \text R} \\[1em] \text G + \text R = \text{nG} \\[1em] \text R = \text G(\text n - 1)

Very Short Answer Type Questions

Question 1

A circular loop of insulated copper wire carrying a current of 0.50 A is placed with its plane perpendicular to a uniform magnetic field B⃗ \vec{\text B} \space= 0.20 T. The radius of the loop is 4.9 cm. Calculate the torque exerted by the magnetic field on the coil.

Answer

Given,

  • Current, I = 0.50 A
  • Magnetic field, B = 0.20 T
  • Radius of the loop, r = 4.9 cm = 4.9 × 10-2 m

The torque on a current-loop in a uniform magnetic field is τ = IAB sin θ, where θ is the angle between the normal to the plane of the loop and the field. As the plane of the loop is perpendicular to B⃗\vec{\text B}, the normal is along B⃗\vec{\text B}, so θ = 0°.

τ=I×πr2×B×sin⁡0∘=0.50×π×(4.9×10−2)2×0.20×0τ=0\tau = \text I \times \pi\text r^2 \times \text B \times \sin 0^\circ \\[1em] = 0.50 \times \pi \times \left(4.9 \times 10^{-2}\right)^2 \times 0.20 \times 0 \\[1em] \tau = 0

Hence, the torque exerted by the magnetic field on the coil is zero.

Question 2

How is radial magnetic field achieved in the moving-coil galvanometer?

Answer

The radial magnetic field is achieved by using cylindrically-cut (concave) pole-pieces of a strong horse-shoe magnet and placing a soft-iron cylindrical core within the coil, without touching it.

Question 3

In a moving-coil galvanometer, what is meant by a radial magnetic field?

Answer

A radial magnetic field is one in which the lines of force are directed along the radii of the cylindrical core, so that the plane of the coil remains parallel to the magnetic field in every position of the coil (θ = 90°). The deflecting torque NIAB on the coil is then independent of its orientation.

Question 4

Why are the pole-pieces of a horse-shoe magnet in a moving coil galvanometer made cylindrical in shape?

Answer

The pole-pieces are made cylindrical (concave) so that, together with the soft-iron core, they make the magnetic field radial. The plane of the coil then remains parallel to the field in every position, the deflecting torque is always NIAB and the current is directly proportional to the deflection (I ∝ φ).

Question 5

What is the resistance of an ideal voltmeter?

Answer

Infinite.

Explanation:
An ideal voltmeter draws no current from the circuit, so that the potential difference to be measured is not changed. This requires its resistance to be infinite.

Question 6

A galvanometer gives full-scale deflection with current Ig. Can it be converted into an ammeter of range I < Ig?

Answer

No.

Explanation:
The shunt required to convert a galvanometer into an ammeter of range I is

S=(IgI−Ig)G\text S = \left(\dfrac{\text I_\text g}{\text I - \text I_\text g}\right)\text G

If I < Ig, then (I − Ig) is negative and S would be negative, which is not possible. A shunt can only divert a part of the current, so the range of the ammeter is always greater than Ig.

Question 7

A student determining the resistance R of a conductor commits the mistake of connecting the voltmeter in series and the ammeter in parallel of R. What readings of ammeter and voltmeter will be obtained? The resistance of the voltmeter is 1500 Ω and the resistance of the ammeter is negligible.

A student determining the resistance R of a conductor commits the mistake of connecting the voltmeter in series and the ammeter in parallel of R. What readings of ammeter and voltmeter will be obtained? The resistance of the voltmeter is 1500 Ω and the resistance of the ammeter is negligible. Galvanometer, Nootan Physics Solutions ICS Class 12.

Answer

Given,

  • emf of the cell, E = 1.5 V
  • Resistance of the voltmeter, RV = 1500 Ω
  • Resistance of the ammeter is negligible

The ammeter of negligible resistance is connected in parallel with R, so it short-circuits R and the whole current passes through the ammeter. The circuit then contains only the voltmeter (1500 Ω) in series with the cell, whose internal resistance is taken as negligible.

By Ohm's law, the current in the circuit is

I=ERV=1.51500=1.0×10−3 AI=1.0 mA\text I = \dfrac{\text E}{\text R_\text V} \\[1em] = \dfrac{1.5}{1500} \\[1em] = 1.0 \times 10^{-3}\ \text A \\[1em] \text I = 1.0\ \text{mA}

The voltmeter reads the potential difference across its own resistance,

V=IRV=1.0×10−3×1500V=1.5 V\text V = \text I\text R_\text V \\[1em] = 1.0 \times 10^{-3} \times 1500 \\[1em] \text V = 1.5\ \text V

Hence, the ammeter reads 1.0 mA and the voltmeter reads 1.5 V.

Question 8

How will you convert a moving coil galvanometer into voltmeter?

Answer

A moving coil galvanometer is converted into a voltmeter by connecting a high resistance R in series with its coil. For a voltmeter of range 0 to V volt, R=VIg−G\text R = \dfrac{\text V}{\text I_\text g} - \text G, where G is the resistance of the galvanometer and Ig the current for full-scale deflection.

Short Answer Type Questions

Question 1

State the principle of a moving-coil galvanometer.

Answer

A moving-coil galvanometer works on the principle that when an electric current flows in a coil placed in a magnetic field, a deflecting torque acts upon the coil whose magnitude depends upon the strength of the current (τ = NIAB). In a radial field the deflection of the coil is directly proportional to the current (I ∝ φ), so the current can be measured from the deflection.

Question 2

Why is the coil in a moving-coil galvanometer wound on an 'aluminium' frame?

Answer

There are two reasons :

(i) Aluminium is a light metal. Hence, a large coil can be suspended by a thin strip, as is necessary for sensitivity.

(ii) When the coil moves, eddy currents are developed in the metallic aluminium frame which oppose the motion of the coil. Hence, on stopping the current, the coil comes to rest rapidly.

Question 3

Why is phosphor-bronze alloy used for the suspension fibre of a moving-coil galvanometer?

Answer

Phosphor-bronze is used for the suspension fibre because :

(i) its torsional constant is small, as required for the sensitivity of the galvanometer;

(ii) its tensile strength is large enough to support the weight of the coil even when the fibre is very fine;

(iii) it is rust proof;

(iv) it is a good conductor of electricity;

(v) it has very less elastic after effect.

Question 4

Why earth's field does not affect the working of a moving-coil galvanometer?

Answer

The coil of a moving-coil galvanometer is suspended in a very strong magnetic field produced by the pole-pieces of a powerful horse-shoe magnet and concentrated by the soft-iron core. The earth's magnetic field is negligible in comparison, so it does not affect the working of the galvanometer.

Question 5

What is the nature of the magnetic field in a moving-coil galvanometer?

Answer

Radial.

Explanation:
The pole-pieces are cylindrically cut and a soft-iron core is placed within the coil, so the lines of force are directed along the radii of the core. The plane of the coil therefore remains parallel to the magnetic field in every position of the coil.

Question 6

What is the advantage of using a radial magnetic field in a moving-coil galvanometer?

Answer

In a radial magnetic field the plane of the coil remains parallel to the lines of force in all orientations of the coil (θ = 90°), so the deflecting torque NIAB remains constant for a given current. In equilibrium NIAB = cφ, i.e., I ∝ φ. Hence, the deflection of the galvanometer is directly proportional to the current in its coil and the scale is uniform.

Question 7

What is the material used in making the core of a moving-coil galvanometer?

Answer

Soft iron.

Explanation:
The core is a cylindrical piece of soft iron fixed within the coil without touching it. Due to the large permeability of soft iron, it concentrates the lines of force and makes the magnetic field radial and strong.

Question 8

What is the function of the soft-iron core within the coil of a moving-coil galvanometer?

Answer

The soft-iron core :

(i) helps in making the magnetic field radial between the magnetic pole-pieces, so that the plane of the coil is always parallel to the field;

(ii) concentrates the lines of force due to its large permeability, thus making the magnetic field strong and the galvanometer more sensitive.

Question 9

Define current-sensitivity of a moving-coil galvanometer.

Answer

The current sensitivity of a moving-coil galvanometer is defined as the deflection produced in the galvanometer when a unit current flows through it,

ϕI=NABc\dfrac{\phi}{\text I} = \dfrac{\text{NAB}}{\text c}

where N is the number of turns, A the area of the coil, B the magnetic field and c the torsional constant of the suspension. Its unit is radian/ampere.

Question 10

State two factors on which the sensitivity of a moving-coil galvanometer depends.

Answer

The current sensitivity of a moving-coil galvanometer is ϕI=NABc\dfrac{\phi}{\text I} = \dfrac{\text{NAB}}{\text c}. Two factors on which it depends are :

(i) the magnetic field B — the sensitivity increases with increase in B;

(ii) the number of turns N of the coil — the sensitivity increases with increase in N.

Question 11

A current I flows in a wire of length L. Prove that, if this wire be bent into a circular coil and suspended in a magnetic field B, then the torque acting on it will be maximum when the coil of 'single' turn is formed, and this maximum torque will be τ=(14π)L2IB\tau = \left(\dfrac{1}{4\pi}\right)\text L^2 \text {IB}.

Answer

Let the wire of length L be wound into a circular coil of N turns, each of radius r. Then,

N×2πr=Lr=L2πN\text N \times 2\pi\text r = \text L \\[1em] \text r = \dfrac{\text L}{2\pi\text N}

Area of each turn,

A=πr2=π(L2πN)2A=L24πN2\text A = \pi\text r^2 \\[1em] = \pi\left(\dfrac{\text L}{2\pi\text N}\right)^2 \\[1em] \text A = \dfrac{\text L^2}{4\pi\text N^2}

The torque on the coil in the magnetic field B is τ = NIAB sin θ, which is maximum for θ = 90°. Hence,

τ=NIAB=NIB×L24πN2τ=L2IB4πN\tau = \text{NIAB} \\[1em] = \text{NIB} \times \dfrac{\text L^2}{4\pi\text N^2} \\[1em] \tau = \dfrac{\text L^2\text{IB}}{4\pi\text N}

As τ∝1N\tau \propto \dfrac{1}{\text N}, the torque is greatest for the least possible number of turns, N = 1, i.e., for a coil of 'single' turn. Then,

τmax=(14π)L2IB\tau_\text{max} = \left(\dfrac{1}{4\pi}\right)\text L^2\text{IB}

Hence, the torque is maximum when a coil of single turn is formed and the maximum torque is τ=(14π)L2IB\tau = \left(\dfrac{1}{4\pi}\right)\text L^2\text{IB}.

Question 12

Why do you not use a galvanometer as it is, as an ammeter?

Answer

A galvanometer is not used as such as an ammeter because :

(i) the resistance of its coil is not very small, so on connecting it in series it would appreciably change the current in the circuit;

(ii) it can measure only a limited current corresponding to the maximum possible deflection of its coil; a larger current may damage it.

Question 13

State how a moving-coil galvanometer can be converted into an ammeter.

Answer

A low resistance, called the 'shunt', is connected in parallel with the coil of the galvanometer. The value of the shunt depends on the required range I of the ammeter,

S=(IgI−Ig)G\text S = \left(\dfrac{\text I_\text g}{\text I - \text I_\text g}\right)\text G

where G is the resistance of the galvanometer and Ig the current for full-scale deflection.

Question 14

Why should an ammeter have a low resistance?

Answer

An ammeter is connected in series in the circuit. Its resistance must be very small compared with the other resistances of the circuit, so that it does not appreciably change the circuit resistance and hence the current which it measures. An ideal ammeter has zero resistance.

Question 15

Why should the resistance of a voltmeter be very high?

Answer

A voltmeter is connected in parallel across the resistance whose potential difference is to be measured. Its resistance must be very high so that it draws negligible current from the circuit and the potential difference to be measured is not changed. An ideal voltmeter has infinite resistance.

Question 16

When an ammeter is put in a circuit, does it read exactly the actual current in the circuit? When a voltmeter is placed across a part of the circuit, does it read exactly the original voltage drop?

Answer

No. Neither instrument reads exactly the original value.

Explanation:
When an ammeter is put in a circuit, its own small resistance is introduced into the circuit. Hence, the current recorded is slightly less than the actual current.

When a voltmeter is placed across a part of the circuit, it draws some current. Hence, the voltage drop recorded is slightly less than the original value.

Question 17

Why is an ammeter connected in series and a voltmeter in parallel to an electric circuit?

Answer

An ammeter is connected in series so that the whole of the current in the circuit passes through it.

A voltmeter measures the potential difference between two points of a circuit, so it is connected in parallel to those points. Due to its high resistance it draws minimum current, so that the potential difference to be measured is not affected materially.

Question 18

What would happen if we connect an ammeter in parallel and a voltmeter in series in a circuit?

Answer

An ammeter has a very low resistance. If it is connected in parallel, it will draw almost the entire current of the circuit and may be damaged.

A voltmeter has a very high resistance. If it is connected in series, it will reduce the current in the circuit to almost zero.

Question 19

Can we increase or decrease the range of a given ammeter?

Answer

We can increase the range of a given ammeter, but we cannot decrease it.

Explanation:
The range is increased by connecting a proper shunt S in parallel with the ammeter, given by S=(IgI−Ig)G\text S = \left(\dfrac{\text I_\text g}{\text I - \text I_\text g}\right)\text G, where G is the resistance of the ammeter, Ig its present range and I the new (increased) range. A shunt can only divert a part of the current, so the range cannot be decreased.

Question 20

Can we increase or decrease the range of a given voltmeter?

Answer

Yes.

Explanation:
The range of a voltmeter is increased by connecting an additional resistance in series with it. The range is decreased by reducing the total resistance (G + R) of the voltmeter, i.e., by connecting a suitable resistance in parallel with its series resistance R.

Note: The textbook says the range is decreased by connecting a resistance in parallel with the voltmeter. A resistance across the voltmeter terminals leaves the full-scale reading Ig(G + R) unchanged; it must be connected across the series resistance R.

Question 21

Of the two identical galvanometers, one is to be converted into an ammeter and the other into a milliammeter. Which of the shunts will be of larger resistance?

Answer

The shunt of the milliammeter will be of larger resistance.

Explanation:
The shunt is given by S=(IgI−Ig)G\text S = \left(\dfrac{\text I_\text g}{\text I - \text I_\text g}\right)\text G. For identical galvanometers, G and Ig are the same, so a smaller range I needs a larger S. In the milliammeter, which has the smaller range, a larger part of the main current passes through the galvanometer coil, so its shunt has the larger resistance.

Question 22

A current-carrying wire of high resistance has an ammeter in series and a voltmeter in parallel. After sometime the wire becomes hot but the ammeter and the voltmeter do not. Give reason.

Answer

The ammeter carries the same current I as the wire, but its resistance RA is very small compared with the resistance R of the wire (RA << R). Hence, the rate of dissipation of energy I2RA in the ammeter is very small compared with the rate I2R in the wire.

The voltmeter has the same potential difference V across it as the wire, but its resistance RV is very high (RV >> R). Hence, the rate of dissipation of energy V2/RV in the voltmeter is very small compared with the rate V2/R in the wire.

Therefore, the wire becomes hot but the ammeter and the voltmeter do not.

Long Answer Type Questions [A]

Question 1

A moving-coil galvanometer consists of a rectangular coil of N turns, each of area A, suspended in a radial magnetic field of flux density B. Derive the expression for the torque on the coil when current I passes through it. Draw suitable labelled diagram.

Answer

Let the rectangular coil PQRS have N turns, with vertical sides PQ = RS = l and horizontal sides QR = SP = b, so that the area of each turn is A = l × b. It is suspended in a radial magnetic field of flux density B, produced by cylindrically-cut pole-pieces and a soft-iron core, and a current I passes through it.

A moving-coil galvanometer consists of a rectangular coil of N turns, each of area A, suspended in a radial magnetic field of flux density B. Derive the expression for the torque on the coil when current I passes through it. Draw suitable labelled diagram. Galvanometer, Nootan Physics Solutions ICS Class 12.

Forces on the sides : The vertical sides PQ and RS are always perpendicular to the field. The force on each turn of either side is IBl, so for N turns,

F1=F2=NIBl\text F_1 = \text F_2 = \text{NIBl}

These forces are equal and opposite, act perpendicular to the plane of the coil and have different lines of action, so they form a deflecting couple. The forces on the sides QR and SP are equal and opposite along the same line, so they cancel.

Torque : If the normal to the plane of the coil makes an angle θ with the field, the perpendicular distance between F1 and F2 is b sin θ. Hence,

τ=NIBl×bsin⁡θτ=NIABsin⁡θ\tau = \text{NIBl} \times \text b\sin\theta \\[1em] \tau = \text{NIAB}\sin\theta

In a radial field the plane of the coil remains parallel to the lines of force in every position, i.e., θ = 90° and sin θ = 1. Therefore,

τ=NIAB\tau = \text{NIAB}

Hence, the torque on the coil in a radial magnetic field is τ = NIAB, independent of the orientation of the coil.

Question 2

Explain the principle and construction of a moving-coil galvanometer. Prove that in a radial field the current in the coil is directly proportional to the deflection of the coil.

Answer

Principle : When an electric current flows in a coil placed in a magnetic field, a deflecting torque acts upon the coil whose magnitude depends upon the strength of the current. From the deflection of the coil, the strength of the current can be computed.

Construction :

Explain the principle and construction of a moving-coil galvanometer. Prove that in a radial field the current in the coil is directly proportional to the deflection of the coil. Galvanometer, Nootan Physics Solutions ICS Class 12.

A suspended-coil galvanometer consists of a rectangular coil of a large number of turns of fine insulated copper wire wound on a light, non-magnetic aluminium frame. The coil is suspended by a thin phosphor-bronze strip from a torsion head connected to the terminal screw T1; its lower end is connected to a fine, loosely wound spring joined to the terminal screw T2. A small light mirror attached to the strip measures the deflection by a lamp and scale arrangement. The coil hangs between the concave cylindrical pole-pieces N and S of a powerful horse-shoe magnet, and a soft-iron cylindrical core is fixed within the coil without touching it.

Current is proportional to deflection : Let the coil have N turns, each of area A, and carry a current I in a field B. The pole-pieces and the core make the field radial, so the plane of the coil is always parallel to the field (θ = 90°) and the deflecting torque is NIAB.

As the coil rotates, the suspension strip is twisted and a restoring torque cφ acts on it, where c is the torsional constant of the strip and φ the deflection. In equilibrium,

NIAB=cϕI=(cNAB)ϕI=Kϕ\text{NIAB} = \text c\phi \\[1em] \text I = \left(\dfrac{\text c}{\text{NAB}}\right)\phi \\[1em] \text I = \text K\phi

where K=cNAB\text K = \dfrac{\text c}{\text{NAB}} is a constant, called the reduction factor of the galvanometer.

Hence, I ∝ φ, i.e., in a radial field the current in the coil is directly proportional to the deflection of the coil.

Question 3

Describe the working of a moving-coil galvanometer. How can its sensitivity be increased?

Answer

Working : The base of the galvanometer is first made horizontal with the levelling screws so that the coil can rotate freely. Light from a lamp falls on the mirror attached to the strip and a spot of reflected light is obtained on a scale. When the current I passes through the coil, a deflecting torque NIAB acts on it in the radial field, and the coil (with the mirror) rotates. The twist in the strip produces a restoring torque cφ, and the coil comes to rest when

NIAB=cϕI=(cNAB)ϕ\text{NIAB} = \text c\phi \\[1em] \text I = \left(\dfrac{\text c}{\text{NAB}}\right)\phi

If the scale is at a distance D from the mirror and the spot of light is displaced through d, then for small φ, 2ϕ=dD2\phi = \dfrac{\text d}{\text D}, i.e., ϕ=d2D\phi = \dfrac{\text d}{2\text D}. As D is kept constant, I ∝ φ ∝ d, so the current is measured from the displacement of the spot.

Increasing the sensitivity : The current sensitivity of the galvanometer is

ϕI=NABc\dfrac{\phi}{\text I} = \dfrac{\text{NAB}}{\text c}

It can be increased by :

(i) increasing B, by using a very strong horse-shoe magnet and placing a soft-iron core within the coil;

(ii) decreasing c, by using a long and fine suspension strip of phosphor-bronze (or quartz);

(iii) increasing N and A, but only up to a limit, otherwise the resistance and the mass of the coil increase undesirably.

Question 4

Why is it that a shunt is required to be connected in parallel with a moving-coil galvanometer to measure the current of a circuit? Establish the equation

Ig=SS+GI\text I_\text g = \dfrac{\text S}{\text S + \text G}\text I

Answer

A galvanometer has an appreciable resistance and gives full-scale deflection for a very small current. If a heavy current flows through it, its pointer may strike the stop pin and break, or its coil may burn. A small resistance S, the shunt, is therefore connected in parallel with it. Most of the current passes through the shunt and only a small part through the coil, and the combined resistance becomes small, so the circuit current is not appreciably changed.

What is the purpose of concave pole-pieces in a moving coil galvanometer? Draw labelled diagrams to illustrate conversion of a galvanometer into (i) ammeter and (ii) voltmeter. Galvanometer, Nootan Physics Solutions ICS Class 12.

Derivation : Let G be the resistance of the galvanometer, I the main current, Ig the current through the galvanometer and (I − Ig) the current through the shunt S. As G and S are in parallel, the potential difference across them is the same,

Ig×G=(I−Ig)×SIgG+IgS=ISIg(S+G)=ISIg=SS+GI\text I_\text g \times \text G = (\text I - \text I_\text g) \times \text S \\[1em] \text I_\text g\text G + \text I_\text g\text S = \text{IS} \\[1em] \text I_\text g(\text S + \text G) = \text{IS} \\[1em] \text I_\text g = \dfrac{\text S}{\text S + \text G}\text I

Hence, Ig=SS+GI\text I_\text g = \dfrac{\text S}{\text S + \text G}\text I, i.e., only the SS+G\dfrac{\text S}{\text S + \text G}th part of the main current flows through the galvanometer.

Question 5

How can a moving-coil galvanometer be converted into (i) an ammeter and (ii) a voltmeter of given ranges? Draw labelled diagram to illustrate the conversions.

Answer

Let G be the resistance of the galvanometer and Ig the current that produces full-scale deflection.

(i) Conversion into an ammeter of range 0 to I :

A small resistance S (shunt) is connected in parallel with the galvanometer.

What is the purpose of concave pole-pieces in a moving coil galvanometer? Draw labelled diagrams to illustrate conversion of a galvanometer into (i) ammeter and (ii) voltmeter. Galvanometer, Nootan Physics Solutions ICS Class 12.

A current Ig passes through the galvanometer and (I − Ig) through the shunt. As they are in parallel,

IgG=(I−Ig)SS=(IgI−Ig)G\text I_\text g\text G = (\text I - \text I_\text g)\text S \\[1em] \text S = \left(\dfrac{\text I_\text g}{\text I - \text I_\text g}\right)\text G

With this shunt, full-scale deflection corresponds to the current I, and the resistance of the ammeter, GSG+S\dfrac{\text{GS}}{\text G + \text S}, is very small.

(ii) Conversion into a voltmeter of range 0 to V :

A high resistance R is connected in series with the galvanometer.

What is the purpose of concave pole-pieces in a moving coil galvanometer? Draw labelled diagrams to illustrate conversion of a galvanometer into (i) ammeter and (ii) voltmeter. Galvanometer, Nootan Physics Solutions ICS Class 12.

When the potential difference V is applied, the current through the galvanometer is Ig,

Ig=VG+RR=VIg−G\text I_\text g = \dfrac{\text V}{\text G + \text R} \\[1em] \text R = \dfrac{\text V}{\text I_\text g} - \text G

With this series resistance, full-scale deflection corresponds to V volt, and the resistance of the voltmeter, (G + R), is very high.

Question 6

An experiment was performed by a student on conversion of galvanometer into an ammeter and voltmeter. The examiner gives the following instructions to the student. State whether the responses of the student, in each case, are correct or incorrect. Give a reason for your answer.

(i) EXAMINER: Increase the range of this ammeter.

STUDENT: Connects a high resistance in series with the given ammeter.

(ii) EXAMINER: I have converted this galvanometer of resistance G into a voltmeter of range 0-1 V by connecting a resistance R in series with it. Now, you convert this voltmeter's maximum range from 1 V to 2 V.

STUDENT: Connects an additional resistance (R + G) in series with R.

(iii) EXAMINER: Take this galvanometer of resistance 72 Ω. Connect a shunt so that only 10% of the total current is allowed to pass through galvanometer.

STUDENT: Connects 8 Ω resistance in parallel to the galvanometer.

Answer

(i) Incorrect.

The range of an ammeter is increased by connecting a small resistance (shunt) in parallel with it, so that the extra current bypasses the meter. A high resistance in series does not increase the range; it only reduces the current in the circuit.

(ii) Correct.

Let Ig be the current for full-scale deflection. For the range 0–1 V,

Ig(G+R)=1...(1)\text I_\text g(\text G + \text R) = 1 \qquad ...(1)

If R' is the additional series resistance for the range 0–2 V,

Ig(G+R+R′)=2...(2)\text I_\text g(\text G + \text R + \text R') = 2 \qquad ...(2)

Dividing Eq. (2) by Eq. (1),

G+R+R′G+R=2G+R+R′=2(G+R)R′=G+R\dfrac{\text G + \text R + \text R'}{\text G + \text R} = 2 \\[1em] \text G + \text R + \text R' = 2(\text G + \text R) \\[1em] \text R' = \text G + \text R

So an additional resistance (R + G) in series with R doubles the range, as the student did.

(iii) Correct.

Here G = 72 Ω and only 10% of the total current passes through the galvanometer, so IgI=110\dfrac{\text I_\text g}{\text I} = \dfrac{1}{10}. For a shunt S,

IgI=SG+S110=S72+S72+S=10S9S=72S=8 Ω\dfrac{\text I_\text g}{\text I} = \dfrac{\text S}{\text G + \text S} \\[1em] \dfrac{1}{10} = \dfrac{\text S}{72 + \text S} \\[1em] 72 + \text S = 10\text S \\[1em] 9\text S = 72 \\[1em] \text S = 8\ \Omega

So the 8 Ω resistance connected in parallel by the student is the required shunt.

Long Answer Type Questions [B]

Question 1

Obtain an expression for torque acting on a current carrying loop in magnetic field in terms of the angle which normal to the plane of loop (coil) makes with magnetic field and in terms of angle which plane of the coil makes with magnetic field.

Answer

Let a rectangular coil PQRS of N turns, with sides PQ = RS = l and QR = SP = b, carry a current I in a uniform magnetic field B⃗\vec{\text B}. The area of the coil is A = l × b.

Obtain an expression for torque acting on a current carrying loop in magnetic field in terms of the angle which normal to the plane of loop (coil) makes with magnetic field and in terms of angle which plane of the coil makes with magnetic field. Galvanometer, Nootan Physics Solutions ICS Class 12.

Forces on the sides : The force on a current-carrying side is F⃗=Il⃗×B⃗\vec{\text F} = \text I\vec{\text l} \times \vec{\text B}. The sides PQ and RS are always perpendicular to B⃗\vec{\text B}, so the forces on them are

F1=F2=NIBl\text F_1 = \text F_2 = \text{NIBl}

These forces are equal, parallel and opposite but have different lines of action, so they form a deflecting couple. The forces F3 and F4 on the sides QR and SP are equal and opposite and act along the same line, so they cancel. Hence, the net force on the coil is zero and only a torque acts on it.

(a) In terms of the angle θ which the normal to the plane of the coil makes with the field :

The perpendicular distance between the lines of action of F1 and F2 is b sin θ. Therefore,

τ=F1×bsin⁡θ=NIBl×bsin⁡θτ=NIABsin⁡θ...(i)\tau = \text F_1 \times \text b\sin\theta \\[1em] = \text{NIBl} \times \text b\sin\theta \\[1em] \tau = \text{NIAB}\sin\theta \qquad ...(i)

With m = NIA as the magnetic moment of the coil, τ = mB sin θ, or in vector form τ⃗=m⃗×B⃗\vec{\tau} = \vec{\text m} \times \vec{\text B}.

(b) In terms of the angle α which the plane of the coil makes with the field :

The normal is perpendicular to the plane of the coil, so θ = 90° − α. Putting this in Eq. (i),

τ=NIABsin⁡(90∘−α)τ=NIABcos⁡α...(ii)\tau = \text{NIAB}\sin\left(90^\circ - \alpha\right) \\[1em] \tau = \text{NIAB}\cos\alpha \qquad ...(ii)

Special cases :

  • When the plane of the coil is parallel to the field (θ = 90°, α = 0°), the torque is maximum, τmax = NIAB.
  • When the plane of the coil is perpendicular to the field (θ = 0°, α = 90°), the torque is zero.

Hence, τ = NIAB sin θ in terms of the angle with the normal, and τ = NIAB cos α in terms of the angle with the plane of the coil.

Question 2

Define radial field and sensitivity of a moving coil galvanometer and also explain the factors on which current sensitivity of a suspended coil galvanometer depends.

Answer

Radial field : A radial magnetic field is one in which the lines of force are directed along the radii of the cylindrical soft-iron core, so that the plane of the coil remains parallel to the field in every position of the coil (θ = 90°). It is obtained by using cylindrically-cut (concave) pole-pieces and a soft-iron core within the coil.

Sensitivity : A galvanometer is said to be sensitive if a small current passed through it produces a sufficiently large deflection.

  • The current sensitivity is the deflection produced in the galvanometer when a unit current flows through it, ϕI\dfrac{\phi}{\text I}. Its unit is radian/ampere.
  • The voltage sensitivity is the deflection produced in the galvanometer when a unit voltage is applied across its coil, ϕV\dfrac{\phi}{\text V}. Its unit is radian/volt.

Factors affecting the current sensitivity : In a radial field a current I through a coil of N turns, each of area A, produces a deflecting torque NIAB. It is balanced by the restoring torque cφ of the suspension strip, where c is its torsional constant. In equilibrium,

NIAB=cϕϕI=NABc\text{NIAB} = \text c\phi \\[1em] \dfrac{\phi}{\text I} = \dfrac{\text{NAB}}{\text c}

Hence, the current sensitivity depends on :

(i) the number of turns N — increasing N increases the sensitivity, but N cannot be increased beyond a limit, otherwise the resistance and the mass of the coil increase undesirably;

(ii) the area A of the coil — a larger area increases the sensitivity, but it is limited for the same reason;

(iii) the magnetic field B — B is made as large as possible by using a very strong horse-shoe magnet and placing a soft-iron core within the coil, which concentrates the lines of force;

(iv) the torsional constant c — c is made as small as possible by using a long and fine suspension strip of phosphor-bronze (or a silvered quartz fibre).

Question 3

Draw diagram and explain construction of suspended coil galvanometer. Why poles of a permanent magnet are concave (curved) in shape in this galvanometer? Explain why phosphor-bronze strip is used.

Answer

Construction :

Explain the principle and construction of a moving-coil galvanometer. Prove that in a radial field the current in the coil is directly proportional to the deflection of the coil. Galvanometer, Nootan Physics Solutions ICS Class 12.

The suspended-coil galvanometer consists of the following parts :

(i) Coil — a rectangular (or circular) coil of a large number of turns of fine insulated copper wire wound on a light, non-magnetic metallic (aluminium) frame.

(ii) Suspension — the coil is suspended by a thin phosphor-bronze strip from a torsion head connected to a terminal screw T1. Its lower end is connected to a fine, loosely wound spring joined to another terminal screw T2.

(iii) Mirror — a small light mirror attached to the lower portion of the strip rotates with it, and its deflection is measured by a lamp and scale arrangement.

(iv) Magnet and core — the coil hangs between the pole-pieces of a powerful permanent horse-shoe magnet NS, which are cut concave cylindrical. A soft-iron cylindrical core is fixed within the coil without touching it.

(v) Case — the whole arrangement is enclosed in a non-magnetic box with a glass front, and three levelling screws are provided at its base.

Why the poles are concave : The concave (cylindrically-cut) pole-pieces, together with the soft-iron core, make the magnetic field radial. The plane of the coil then remains parallel to the field in every position, so the deflecting torque is always NIAB. In equilibrium NIAB = cφ, giving I ∝ φ, so the deflection is directly proportional to the current and the scale is uniform. The core also concentrates the lines of force and makes the field strong.

Why phosphor-bronze strip is used :

(i) Its torsional constant (torsion couple per unit twist) is small, which makes the galvanometer sensitive.

(ii) Its tensile strength is large enough to support the coil even when the strip is very fine.

(iii) It is a good conductor of electricity, so it also serves to lead the current into the coil.

(iv) It does not oxidise (is rust proof) and has very less elastic after effect.

Long Answer Type Questions [C] (Passage Based)

Question 1

A galvanometer can be converted into voltmeter of given range by connecting a suitable resistance Rs in series with the galvanometer. Series resistor (Rs) increases range of voltmeter and the effective resistance of galvanometer. It also protects the galvanometer from damage due to large current.

Voltmeter is a high resistance instrument and it is always connected in parallel with the circuit element across which potential difference is to be measured.

In order to increase the range of voltmeter n times, the value of resistance to be connected in series with galvanometer is Rs = (n−1)G(\text n - 1)\text G.

(i) There are 3 voltmeters A, B and C having the same range but their resistance are 5,000 Ω, 10,000 Ω and 20,000 Ω, respectively. Which one is the best voltmeter amongst them?

(ii) A milliammeter of range 0 to 25 mA and resistance of 10 Ω is to be converted into a voltmeter with a range of 0 to 25 V. What resistance should be connected in series with it?

(iii) A voltmeter is of resistance R Ω. What resistance should be connected in series with it to increase its range to 3 times?

(iv) What is the resistance of an ideal voltmeter?

Answer

(i) Voltmeter C (20,000 Ω) is the best.

Explanation:
A voltmeter is connected in parallel and should draw as little current as possible from the circuit. C has the highest resistance, so it draws the least current and gives the most accurate reading.

(ii) Given,

  • Full-scale current, Ig = 25 mA = 25 × 10-3 A
  • Resistance of the milliammeter, G = 10 Ω
  • Required range, V = 25 V

The resistance to be connected in series is

R=VIg−G=2525×10−3−10=1000−10R=990 Ω\text R = \dfrac{\text V}{\text I_\text g} - \text G \\[1em] = \dfrac{25}{25 \times 10^{-3}} - 10 \\[1em] = 1000 - 10 \\[1em] \text R = 990\ \Omega

So, a resistance of 990 Ω should be connected in series with it.

(iii) Here the resistance of the voltmeter is G = R Ω and n = 3. The resistance to be connected in series is

Rs=(n−1)G=(3−1)RRs=2R\text R_\text s = (\text n - 1)\text G \\[1em] = (3 - 1)\text R \\[1em] \text R_\text s = 2\text R

So, a resistance of 2R Ω should be connected in series with it.

(iv) Infinite.

Explanation:
An ideal voltmeter draws no current from the circuit.

PrevNext